EdenFantasys Newsletter Subscription Form
Take 20% off your order now - Get early access to deals and sales
Home>mall>Tools, Industrial & Scientific
0Ogusta

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

4.3534
$12.99 / $15.85
  • *Name:

  • *Email:

  • *Phone:

  • *Quantity:

  • *Content:

  • Attachment:

    Supports JPG, JPEG, PNG, PDF, EXCEL, WORD, RAR, ZIP, 7z formats

$8.99 / $15.85
Shipping to: United States | Express delivery: 7-12 business days | Standard delivery: 15-25 business days

Oñemo'ã porãva

Jopói libre
Jopói libre oĩjeyvéva ejogua vove
Mba'e rembosa'irã
Mba'e rembosa'irã libre $9.9 rire
Mba'e devolución rehegua
Oñemoneĩ devolución 40 ára peve og̃uahẽ rire. Jopói personalizado ndojejapói devolución. Jopói ejogua cupón ndive oñemoneĩ cambio añoite.

Jopói libre

Eg̃uahẽ porã Roymall-pe, ne renda jopói porã joguápe. Rohechakuaa ha roaguyje ne pytyvõ, ha roñe'ẽ aguyje jopói libre ndive. Ejogua vove, rejoguáta mba'eporã porã ha reñemomba'e jopói libre ndive. Eheka ore apopyrã ha ejuhu ne jopói perfecto.

Mba'e rembosa'irã

Rojapo tembiapo rembosa'irã 2 ára peve.Ára sapy'agua oñemboare 2 ára.Oñemboare 5-7 ára mba'apo (Lunes a Viernes).Oñemboare sapy'a tetã ambuéva rupi.

1. Devolución ha cambio

Roñemoneĩ devolución Roymall-gui añoite. Jopói libre ndojejapói devolución. Ejapo devolución oimeraẽva jopói ojeipurúva'ỹre.Roñemoneĩ devolución 3-5 ára mba'apo peve.Jopói personalizado ndojejapói devolución.Eñe'ẽ ore ndive. service@roymall.com térã Whatsapp: +8619359849471

2.Devuelta

Reguereko devuelta oimeraẽva jopói ojeipurúva'ỹre. Mba'e rembosa'irã ndojejapói devuelta.Eñe'ẽ ore ndive. service@roymall.com térã Whatsapp: +8619359849471
Features:

- Wide range of applications: Can measure the power, current, voltage, temperature, etc. of connected appliances,can also set timing and check battery,and can clearly see the power consumption.
- Full viewing angle color LCD screen.
- Made of nylon material, durable,stable installation.
- The split type transformer has a buckle for easy install and assembly.
- The closed type transformer needs to be threaded from the center of the transformer circle.


Specification:

Model: KWS-AC300-20A

Model: KWS-AC300-100A

Current:0-20A

Current:0-100A

Voltage: 50-300 (V)

Voltage: 50-300 (V)

Electricity: 0.01-19999kwh

Electricity: 0.01-19999kwh

Power: 0-3kw

Power: 0-30kw

Timing: 0-200h

Timing: 0-200h

Temperature: 10℃-99℃

Temperature: 10℃-99℃

Weight:65g

Weight:95g


Package included:

1 x Digital Voltmeter

Details Pictures:

Ejogua Paypal ndive
Tools, Industrial & Scientific Ranking

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

KEWEISI AC 50~300V 20A/100A Digital Electricity Meter Voltmeter Ammeter With CT Power Current Voltage Temperature Measurement

Customer Reviews

4.90 out of 5
See all 274 reviews
Write a Review
  • All Reviews (274)
  • Image ( 2 )
  • Video (0)
  • All Star
    • All Star(274)
    • 5 Star (2)
    • 4 Star (0)
    • 3 Star (0)
    • 2 Star (0)
    • 1 Star (0)
Sort by:
Top Review
  • Top Review
  • Most Helpful
  • Most Recent
Reviews only from your country (United States)
|
Show Original

A part of the review has been auto-translated.

  • 24/09/2020

    Great product, really useful.
    really poor packaging, the box arrived completely smashed.
    Thank god, it was not damaged.
    inappropriate package for something electronic with a screen, it could have been completely busted, be more careful.

    Comments (1)
    Show Original
  • 04/05/2021

    este produto veio usado, todo puido, cheio de manchas e o produto não vem com a bubina .
    não reparei se estava como usado na compra, acredito que não.

    Comments (0)
    Show Original
Show:
    12...30

    Total 0 pages

    Go to page

    Go
    Customer Q&As
    Can't find your answer? Ask a new questionorCustomer Service

    Tips:For questions about your order, place of delivery, product discount, taxation, delivery time, warranty, shipping, payment, exchange rate, and other questions unrelated to the product, please contact customer service.

    showing 1-30 of 30 |
    Show Original

    A part of the QA has been auto-translated.

    • 0
      Q: Do I need three pieces seperately for all three phases?
      A:
      No,it didn't.
      Answered by Laurence on 03/09/2020Helpful (0)
    • 0
      Q: Is it IP 65
      A:
      No
      Answered by BG042333884 on 04/12/2021Helpful (0)
    • 0
      Q: solar will it mesure power from solar cells back to the grid ?
      A:
      Solar cells give DC. After Your inverter to the grid AC might be measured. The transformer would measure current both direction, but care the connection scheme. This is intended to follow your consumption from grid.
      Answered by PanRider on 30/11/2020Helpful (0)
    • 0
      Q: Does the display stay on permanently or do you need to press the button every time to activate it?
      A:
      The display is always on and if there is a power failure it will carry on from where it left off once the power is restored. You will not loose the information.
      Answered by BG413212503 on 05/10/2020Helpful (0)
    • 0
      Q: can you confirm --> it will measure also feedback to the grid , from the solar panels correctly
      A:
      Hi, can I use this device to monitor my house electric use. I have a 200 amps panel??
      Answered by Junior on 16/09/2020Helpful (0)
    • 0
      Q: Can this device run on generator supply too ?
      A:
      As said the device will function within the specifications as described. Not certain how the temp. measure sensor will be mounted. Suggest to mount the device direct on the frame to minimise vibration which could damage it .
      Answered by zs4bos on 13/06/2022Helpful (0)
    • 0
      Q: When the AC Load wire (instead of Nuetral wire) is taken through the switching transformer (not round shaped transformer), will the meter display Current consumption in meter?
      A:
      the Story of the S
      Answered by BG042333884 on 04/12/2021Helpful (0)
    • 0
      Q: what temperature does this read? does this read the heat of unit itself? ambient temperature? or does this need a thermocouple/temperature probe to read an external temperature?
      A:
      Thermocouple unit plugs into the unit with a small white 2 pin connecter. Temp reading will come from wherever you place it, inside DB Board or the end of the probe can stick out measuring the air temp.
      Answered by BG413212503 on 16/12/2020Helpful (0)
    • 0
      Q: Has anyone hooked this up to a Sonoff or eps8266/esp32/rPi etc?
      A:
      Interestingyou ask this, as I want to do exactly the same thing. There's no default, user facing, method. I've yet to take it to bits to look for some other interface - likely debug test points on the PCB. Might get lucky and there's a socket inside. You mention Rpi - as a worst case, I was going to use a pi with a elcheapo webcam runing a python script to visually read the display. Well, a bank of displays, I've more than one. When I get that far through my turbine build, I'll be back to divulge my learnings. If you get there first, pop back and let me know.
      Answered by BG161213372 on 31/08/2022Helpful (0)
    • 0
      Q: can this unit detect a spike in current say less than a second. For example when a compressor start? I need to know the max current draw. can it log max values
      A:
      The consumption value is refreshed approx. 3 times per second and it is difficult to figure out the maximum value. The maximum value is not saved.
      Answered by bolasic on 04/02/2021Helpful (0)
    • 0
      Q: Is there a split CT with a 1 inch or 25mm I.D. that would work with this unit?
      A:
      You can order it with either split or close CT. From CN store sure.
      Answered by PanRider on 04/08/2021Helpful (0)
    • 0
      Q: Hi. I purchased this product. Excellent product. I want to extend the wire length of wire for transformer. What thickness of wire I can purchase?
      A:
      bastante efectivo facil visualización de los datos
      Answered by BG042333884 on 04/12/2021Helpful (0)
    • 0
      Q: How to use this in 220V 50/60 Hz with wire is Line to Line or Live(hot) 1/live(hot) 2 without Neutral? Thanks
      A:
      Just put one of the wires through the split coupler.
      Answered by BG543416191 on 26/12/2020Helpful (0)
    • 0
      Q: Hello, the instrument reads double the current delivered. Is there any way to regulate it?
      A:
      make sure the CT is around the hot lead only. if not it will report false measurements.
      Answered by Philiski on 16/04/2021Helpful (0)
    • 0
      Q: Does it display power factor?
      A:
      I think according to the instructions it can measure kWh energy or power factor PF. I bought it but haven't installed it yet, and the instructions say that it is possible to choose.
      Answered by JOZE on 21/03/2021Helpful (0)
    • 0
      Q: Wired as per included diagram the screen lights up - with the probe connected, displays temperature - but I'm getting no readings through the CT. At all. Any clues? On a different note, anyone seen a device like this that speaks MQTT or is intended to couple to a microcontroller for logging etc?
      A:
      Pass the wire you want to measure on the CT through the ring current transformer. Then connect the power adapter in place.
      Answered by unandi on 28/07/2022Helpful (0)
    • 0
      Q: Hi I received my parcels but do I have to buy the CT for 100A separately or is it included
      A:
      You can see if the properties you buy include CT.
      Answered by The seller on 04/11/2021Helpful (0)
    • 0
      Q: Does this unit have an interface for analogue or digital data out?
      A:
      It hasn't.
      Answered by PanRider on 23/08/2021Helpful (0)
    • 0
      Q: Do you have 3P 4W 380-400 V. metering type ?
      A:
      You'd done better to ask Customer Service Team.
      Answered by PanRider on 11/07/2021Helpful (0)
    • 0
      Q: Lehet-e fizetni utánvéttel forintban?
      A:
      No.
      Answered by smudger149 on 07/05/2021Helpful (0)
    • 0
      Q: So, 10A or 100A ?
      A:
      You can select when purchasing whether you want the 10amp or 100amp versions as well as a closed current transformer or one that can open and go around the wire instead of taking the wire out and feeding it through and connecting again
      Answered by BG413212503 on 09/11/2020Helpful (0)
    • 0
      Q: Good night, I bought a device with you and it came defective. He calls, but doesn't measure anything. I await an urgent response. Device name: Keweisi Model: KWS-AC300
      A:
      Hi, maybe you can contact with the Banggood customer service team. https://www.banggood.com/Contact-Us_hi111
      Answered by Waits on 04/11/2020Helpful (0)
    • 0
      Q: Received the product more it's not working just plugs more not branding anything
      A:
      Hi, maybe you can contact with the Banggood customer service team. https://www.banggood.com/Contact-Us_hi111
      Answered by Blithe on 04/11/2020Helpful (0)
    • 0
      Q: can this be changed to read Fahrenheit? or only Celsius
      A:
      Yes, You can change C-F
      Answered by PanRider on 31/10/2020Helpful (0)
    • 0
      Q: Good morning, the instrument reads twice the current output.
      A:
      Please can you ask me the question in English and I will try to help you.
      Answered by BG413212503 on 18/10/2020Helpful (0)
    • 0
      Q: Hello, do you also have a model with 3 phase measurement? So 3 converters (3 coils) to a measuring device. For measuring three phase current.
      A:
      NO
      Answered by Quaffheep1712 on 06/11/2020Helpful (0)
    • 0
      Q: I can't read Temperature !!! No sensor in the box !? But all others function works on my 3 units well receive ..!
      A:
      There is a sensor in the box. My product has once. I put in electronic box and read temp. All funcrion work well.
      Answered by sang28ckt on 25/09/2020Helpful (0)
    • 0
      Q: LIke the idea but looking for something more int he range of 1vdc to 100vdc with current at 500mA to 15Amps?
      A:
      CTs cannot measure DC, by laws of physics. You need a shunt with voltage sensing to calculate the current, or a hall effect sensor setup with de-gaussing etc.
      Answered by BG122178544 on 09/09/2020Helpful (0)
    • 0
      Q: hello I need 32 a
      A:
      No answer yet.
    • 0
      Q: Hello. I'm looking for this meter with the CT round like the one in the photo but to work with car batteries (0-24VDC) and (0-100ADC). Where can I find it?
      A:
      This will not work with DC. Only AC!
      Answered by paulntexas on 06/09/2020Helpful (0)